Fire-by-design AWEIS Manuel d'utilisateur Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 13
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
10
Operation
Fire Feature Start Up
1. Prior to turning appliance on visually inspect fire feature to ensure debris such as leaves or other
combustible material has not collected inside the feature which could burn and emit embers once the
fire feature is turned on. Also ensure any person standing close to the fire feature is aware you will be
turning the fire feature on prior to actually turning it on.
2. Turn fire feature on by turning on the electrical device used to power the fire feature.
Sequence of Operation during Ignition
- Power is applied
- Hot Surface Igniter (Glow Plug) becomes hot and 4 seconds later the Pilot Gas Valve opens
- Within 10 seconds of power application Pilot Flame should be visible (at night only)
- Within 10 seconds of Pilot Flame Ignition burner (fire ring/burner bar) should ignite
Fire Feature Shutdown
1. Turn fire feature off by turning off the electrical device used to power the fire feature.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace
any part of the control system and any gas control which has been under water.
WARNING
HOT DO NOT TOUCH - SEVERE BURNS MAY RESULT - CLOTHING IGNITION MAY RESULT
- CAREFULLY SUPERVISE children in same area as the appliance.
- Alert children and adults to hazards of high temperatures.
- Clothing or other flammable materials should not be hung from the appliance or placed on or near the
appliance.
WARNING
The appliance should be inspected before use and at least annually by a qualified service technician.
Any guard or protective device removed for servicing must be replaced prior to operation.
Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
WARNING
If fire feature fails to turn off completely (small flames still visible)
Turn off gas supply using the manual gas shutoff.
Vue de la page 9
1 2 ... 5 6 7 8 9 10 11 12 13

Commentaires sur ces manuels

Pas de commentaire